Logo

Noise Control & System Protection

AVC2: Overview | Specifications

Specifications

Frequency Response
20Hz - 30Hz ±0.5dB
DistortionO/P level Attenuation
(THD and noise) freq. 1kHz0dBu0db <0.01%
 0dBu12dB<0.015%
 0dBu30dB<0.05%
Noise
20Hz-20kHz Equiv. input noise <-90dBu
Inputs
Electronically balanced, connect negative to screen for unbalanced use.
Input impedanceBalanced20K ohms
 Unbalanced10K ohms
Maximum input level+22dBu
Clip indicatorIndicates @ +20dBu
Outputs
Electronically balanced, connect negative to screen for unbalanced use.
Source impedance100 ohms
Minimum load impedance600 ohms
Operating Threshold Range
High Range Average level adjustable+5dBu-2dBU
Low RangeAverage level adjustable-8dBu-14dBu
Attenuator range
-3dB -6dB -9dB -12dB -15dB -18dB -24dB -30dB
Control Chain
A control chain with a flat frequency response Linear, "A" weighted,
or a combination of both may be selected to control the attenuators.
(An aux. input to control the unit can be offered as an option, contact Formula Sound).
Aux Connections
1 & 2 Mute
3 & 4 Output control
5 & 6 Remote warning 3dB before threshold 10V DC
Power
220-240V AC (110V to order).
Mains Fuse 250mA slow blow
I.E.C. Mains Connector
Finish
Front and Rear panels:Black anodised aluminium
with etched silver notation which will not rub off in use.
Case:Black plastic-coated steel.
Dimensions
19" Rack mounting 1RU Width 482mm (19") Depth 200mm (7.9") Height 44mm (1.75")

N.B. If a signal generator is used as the source for making adjustments to the operating threshold, the threshold will be approx. 6dB lower than using a music source due to the averaging measurement which the unit uses for control. For operation outside the above ranges contact Formula Sound Ltd.

Formula Sound reserve the right to alter specifications at any time without notice.